Pressure Gauge Refrigeration Digital Vacuum Pressure Manifold Tester Meter HVAC Temperature Tester Valve Tool Kit ,Easy to Use

★★★★★ 4.4 38 reviews

US$66.74
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by criticalmediartstudio.com
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
US$66.74
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Aug 15
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by criticalmediartstudio.com
Free 30-day returns Details

Product details

Management number 238234446 Release Date 2026/07/11 List Price US$66.74 Model Number 238234446
Category

<p>The instrument can measure double pressure (gauge pressure) at the same time, as well as dual temperature measurement (need test clip,not include), with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit, to facilitate different needs. Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data. Also it tests percentage of vacuum measurement; pressure leak measurement, leak time speed record. It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right. </p><p>EC/EN61010-1 safety standards for design and production. </p><p>1) The pressure measured by the digtal manifold pressure tester is gauge pressure. </p><p>2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar). </p><p>3) The limit pressure is 10 Mpa (100 bar). </p><p>4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ). </p><p>5) Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed </p><p>hoses does not match the pressure requirement, you can use suitable replacements for testing. </p><p>6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields. </p><p>7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring. </p><p>8) Please wear qualified protective equipment to protect user during testing. </p><p>9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases. </p><p>Product specifications </p><p>Pressure test: gauge pressure </p><p>Pressure test unit: Kpa; Mpa; bar; inHg; PSI. </p><p>Pressure test range: 0 Kpa 6000 Kpa </p><p>Pressure test resolution: 1 Kpa </p><p>Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt </p><p>Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;) </p><p>Vacuum test: relative vacuum </p><p>Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. </p><p>Vacuum test range: -101 Kpa 0 Kpa </p><p>Vacuum test resolution: 1 Kpa </p><p>Temperature test unit: °C (Celsius), °F (Fahrenheit) </p><p>Temperature test range: -40°C150°C (-40°F302°F) </p><p>Temperature test resolution: </p><p>0.1°C (-40°C99.9°C), 1°C (100°C150°C) </p><p>0.1°F (-40°F99.9°F), 1°F (100°F302°F) </p><p>Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt </p><p>Built-in 89 kinds of refrigerant NIST: According to American NIST standard </p><p>Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not include </p><p>Dimensions: 170*110*50mm weight: 950g </p><p>Packing list: </p><p>DY517 </p><p>1* Refrigerantion Digital Manifold Gauge </p><p>1* User manual</p><p>Related Products:manifold gauge set,r410a refrigerant,ac gauge set,r22 refrigerant,refrigerant gauges,ac manifold gauge set,r12 refrigerant,a/c gauge set,hvac manifold gauge set</p>

  • The intelligent electronic refrigerant group instrument is an auxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout, multi-unit switching, multi-mode function and built-in refrigerant database.
  • The instrument uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability.
  • Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation.
  • Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility.
Display LCD
Brand LilyStore
Features Easy To Use
Power type Battery
Material Product Details
Weight 0.35 oz
Has written warranty No
Model DY517

Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Customer ratings & reviews

4.4 out of 5
★★★★★
38 ratings | 16 reviews
How item rating is calculated
View all reviews
5 stars
81% (31)
4 stars
5% (2)
3 stars
2% (1)
2 stars
1% (0)
1 star
11% (4)
Sort by

There are currently no written reviews for this product.